Firing Capacity |
>100,000 fireworks |
Firing Timeline |
Max. 9:59:59.000 |
Computer Edit |
Windows XP, 7, 8.0, 8.1, 10 |
Section |
10 sections |
Input Melody |
Yes |
Combine Melodies |
Yes |
Zoom in and zoom out Timeline |
Yes |
Edit scripts according to melodies |
Yes |
Edit melodies |
Yes |
Create Masters |
Yes, Max.50 units, 2-digital Logic ID
|
Create Firing Modules |
Yes, Max.2500 units, 1-4 digital Logic ID
|
Generate Firing Points in bulk |
Yes, no limitation |
Generate Firing Points individually |
Yes |
Use Mouse to generate Firing Points |
Yes |
Use Spacebar to generate Firing Points |
Yes |
Firing Point adjustment / delete |
Yes |
Firing Time Error adjustment |
Yes, from +9.999 seconds to -9.999 seconds |
Firing Point list |
Yes |
Master and Module list |
Yes |
Tree Diagram |
Yes |
Import firing script |
Yes, csv or xls format |
Export firing script |
Yes, xls format |
Print firing script |
Yes, A4 size |
Computer Control Firing |
Windows XP, 7, 8.0, 8.1, 10 |
Part Firing |
Yes |
Music Firing |
Yes |
Program Firing |
Yes |
Steper Firing |
Yes |
Dividual Firing |
Yes |
DEMO Firing |
Yes |
Instant Firing |
Yes |
Countdown Firing |
Yes |
Scheduled Time Firing |
Yes |
Computer Management |
Windows XP, 7, 8.0, 8.1, 10 |
Test/Automatic Test |
Yes |
Logic ID assign / reassign |
Yes |
Download Script |
Yes |
Upload Script |
Yes |
GPS Timing |
Yes |
GPS Positioning |
Yes |
Computer Monitoring |
|
RF Signal Strength |
0-100% |
Firing Voltage |
0-24V |
Interal LIPO battery voltage |
0-8.4V |
External power voltage |
0-36V |
Synchronization status |
Yes |
Connected igniter status |
OK, short or broken |
Communication |
|
Computers and Masters |
Bidirectional RF, LAN, Ethernet and Wired Cable |
Bidirectional RF |
Range 2,000m-10,000m |
Wired |
RS485 and USB, Distance Max.1,000m |
LAN |
Yes |
Ethernet |
Yes |
Extendable |
Yes |
Masters and Slaves |
LoRa Wireless, range 100-300m / RS485, range 1000m
|
Synchronization |
|
Automatic Synchronization |
Yes |
Manually Synchronization |
Yes |
Master |
|
Test/Check Test Result |
Yes |
Assign/Reassign Logic IDs |
Yes |
Internal Battery |
18650 battery, 7.4V, rechargeable |
External Power |
36V DC |
RF Communication |
Yes |
LAN/Ethernet Communication |
Yes |
RS485 Communication |
Yes |
Fallen-protective |
Yes |
Waterproof |
Yes |
Slave-Firing Module |
|
Cues |
32 cues, from A1 to A8, B1 to B8, C1 to C8 and D1 to D8 |
Test/Check Test Result |
Yes, Visible through LEDs |
Firing Power |
Super Capacitor, 24V |
Firing Voltage |
Max.24V |
Firing Current |
Max.20A |
Internal Battery |
18650 battery, 7.4V, rechargeable |
External Power |
12-36V DC |
Communication |
RF Wireless, RS485 |
Wiring Terminals |
EasyClips |
Fallen-protective
|
Yes |
Waterproof |
Yes |
AC-DC Smart Charger |
|
Capacity |
150 Watt or 320 Watt |
Input |
90-240V AC |
Output |
36V DC |
Overload Protection |
Yes |
|
|